Since 2005, 16 Yeares Fire Alarm and Suppression System Manufacturer&Whole Solution Designer
We supply whole fire alarm and suppression system include conventional fire alarm system, addressable fire alarm system, emergency light system, FM200 gas suppression system, fire pump, fire hose reel and cabinet.
  • Home
  • Products
    ASENWARE Fire Alarm Control System are intelligent system which are designed to make it suitable for most of applications. It’s user friendly functionality makes it suitable to program and configure the devices. 7 ” touchscreen display gives the information for fire alarm, trouble , supervisory and other related information all the
    time.This system fully complied with the requirement of EN 54-2 and EN 54-4.
    ASENWARE Fire Pump Series provide fire departments or private users with the ability to pump from any water source.
    The AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 24 standard. 
    ASENWARE Centralized Monitoring Emergency Luminaire System is designed for managing, monitoring and controlling emergency lights automatically. 
    Asenware FP300 series is a LPCB addressable fire alarm system with one loop of 324 addressable points, comply with EN 54 standard.
    ASENWARE fire fighting telephone system is the special communication equipment for fire fighting
    ASENWARE Heat Detector is photo-electronic detector using a state-of-the-art optical sensing chamber. 
  • Project
  • Newsroom
  • About Us
  • Contact
Two Wire Addressable fire alar...
Home > Products > Two Wire Addressable fire alarm control system
Addressable Smoke Detector AW-D101
Asenware AW-D101 smoke detector is an intelligent smoke detector, which can be configured with Asenware AW-FP100 Series Addressable Fire Alarm Control Panel. Each point (devices) can be given specific...
  • Asenware AW-D101 smoke detector is an intelligent smoke detector, which can be configured with Asenware AW-FP100 Series Addressable Fire Alarm Control Panel. Each point (devices) can be given specific ID, which allows the panel to continuously monitor specific detector location (point). It reduces the maintenance cost and makes it easier to maintain the system.
  • Addressable Smoke Detector features:

    • Addressable-analog communication
    • Low standby current for continuous
    monitoring (≤2.5mA)
    • Two-wire connection
    • Two LEDs (RED), blinks in normal condition
    and becomes stationary during fire
    • Remote test from Panel

    Spacing
    Spacing of detector must be followed by standard EN 54 or NFPA 72. NFPA 72
    suggests for low airflow application spacing of 9.1 m for ceiling height up to 3.15 m can
    be applicable. However, please follow the specific codes and local codes for specific
    applications.
  • Addressable Smoke Detector Technical parameters:

    Model No. AW-D101
    D/C 1712
    Operating Voltage Range 18V-28VDC   
    Alarm Current ≤3mA
    Work Current ≤2.5mA
    Temperature -10℃ to 50℃
    Smoke Sensitivity 0.1-0.15 dB/m
    Standard Number Ref EN 57-7:2000
    Size 99.80mm
    Terminals Connection No 6: Remote Indicator+
    No 3: Remote Indicator-
    No 2: Loop IN+ 
    No 5: Loop IN-

    smoke detector installation smoke detector placement

    AW-D101 addressable detector use a separate base to simplify the installation and
    maintenance. For proper installation, terminal connections to be followed as shown
    below

    smoke detector installation