Linear Heat Detection System
Digital Type linear Heat Detectors
Compared with other kinds of detectors. MS1000 Digital Linear Heat Detector provides a very-early alarm detecting function to the protected environment, The detector can be known as an intelligent "switch" type detector. The polymers between the two condu
Product overview
1.Compared with other kinds of detectors. MS1000 Digital Linear Heat Detector provides a very-early alarm detecting function to the protected environment, The detector can be known as an intelligent "switch" type detector. The polymers between the two conductors will break down at specific fixed temperature allowing the conductors contact, the shot circuit will initiate the alarm. The detector has a continuous sensitivity. The sensitivity of linear heat detector will not be influenced by the environment temperature changing and the length of detection cable using. It does not need to be adjusted and compensation. The detector can transfer both alarm and fault signals to control panels normally with DC24V or without DC24V.
Linear Heat Detection Cable Classification
Conventional Type:This type of Linear heat detection cable is the most widely indoor used with strong stability.
CR/OD Type:CR/OD Type not only has good UV resistance and good weather resistance, strongly recommended for outdoor using even under bad weather conditions, but also with high performance of acid resistant, alkali-resistant, salt spray resistant.
EP Type:Explosion Proof Type. Two main application environments: harsh EMI environment and explosive hazardous environment. The outer jacket of this type is protected by woven metal mesh with good performance of anti-EMI and eliminating the surface static of the Linear heat detection cable. We can use this type Linear heat detection cable in explosive hazardous environment with safety fence. During the installation, please make grounding connection of the woven metal mesh. Used in harsh EMI environment, single end grounding connection or double ends grounding connection should be specified after analysis of the interference sources.

2.Structure
Intertwisting two rigid metallic conductors which are covered by NTC heat sensitive material, with insulative bandage and outer jacket, here comes the Digital Type Linear Hear Detection Cable . And the different model numbers depend on the variety of materials of outer jacket to meet different special environments.


Product Features
Features and benefits
  • Industrial safety design
  • Electrical interface with low power consumption design .Real-time monitoring
  • Working with DC24V supply or without DC24V supply
  • Fast response time
  • No alarm temperature compensation needed
  • Compatible to any kind fire alarm system
  • Plenty levels of alarm temperatures:from 68C to 180C
Technical parameters
Operating Voltage: DC 24V
Allowed Voltage Range: 16VDC-28VDC
Standby Current: < 20mA
Alarm Current: < 30mA
Fault Current: < 25mA
Maximum Relative Humidity for Long Term Use: 90%-98% . IP Rating: IP66
Alarm temperatures: 68°C, 88°C, 105°C, 138°C & 180