Since 2005, 16 Yeares Fire Alarm and Suppression System Manufacturer&Whole Solution Designer
We supply whole fire alarm and suppression system include conventional fire alarm system, addressable fire alarm system, emergency light system, FM200 gas suppression system, fire pump, fire hose reel and cabinet.
  • Home
  • Products
    ASENWARE Fire Alarm Control System are intelligent system which are designed to make it suitable for most of applications. It’s user friendly functionality makes it suitable to program and configure the devices. 7 ” touchscreen display gives the information for fire alarm, trouble , supervisory and other related information all the
    time.This system fully complied with the requirement of EN 54-2 and EN 54-4.
    ASENWARE Fire Pump Series provide fire departments or private users with the ability to pump from any water source.
    The AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 24 standard. 
    ASENWARE Centralized Monitoring Emergency Luminaire System is designed for managing, monitoring and controlling emergency lights automatically. 
    Asenware FP300 series is a LPCB addressable fire alarm system with one loop of 324 addressable points, comply with EN 54 standard.
    ASENWARE fire fighting telephone system is the special communication equipment for fire fighting
    ASENWARE Heat Detector is photo-electronic detector using a state-of-the-art optical sensing chamber. 
  • Project
  • Newsroom
  • About Us
  • Contact
LPCB approved addressable fire...
Home > Products > LPCB approved addressable fire alarm control system
Addressable smoke and heat combined detector AW-ASH2188
AW-ASH2188 Addressable smoke and heat combined detector is a mated product of the 2188/2100 series fire alarm control panels.
  • AW-ASH2188 Addressable smoke and heat combined detector (Detector here under) is a multi-complex by the smoke detector sensor and semiconductor temperature sensors from the process structure and together constitute the circuit structure.
    It not only has a photoelectric smoke detector performance, and both temperature fire detector performance.
    This detector is for the promise of the second bus system, with the company's 2188 series of alarm controller supporting.


  • Addressable smoke and heat combined detector features:

    1. Electronic coding, project commissioning simple and reliable;
    2. The Promise of wire bus;
    3. With the key components of self-diagnostic function;
    4. With drift compensation function and the accumulation of dust pollution reporting functions.
  • Addressable smoke and heat combined detector Technical parameters:

    1. perating voltage: 24V (pulse modulation);
    2. Operating current: ≤0.5mA (monitoring status) or <1.5mA (alarm status);
    3. Sensing technology: the use of photoelectric sensors and temperature sensors dual sensor technology, thermal type: A2;
    4. Weight: about 100g;
    5. External dimensions: diameter: 100mm, height: 55mm (with the base);
    6. Encoding: Electronic, coding range is 1 to 324;
    7. Operating environment: Indoor, temperature: 10℃~+50℃; relative humidity: ≤95% (40℃±2℃, without condensation);
    8. Wiring: Promise of wire;
    9. Installation height: ≤8m;
    10. Shell Material: ABS;
    11. Protection area: about 60m². For details, see related provisions in GB50116-98 Code for Design of Automatic Fire Alarm System;
    12. Matched host machine: fire alarm control panel (such as AW-AFP2188, AW-AFP2100).